BAD SELLER - BUYER BEWARE
125kva MQ- had it shipped 6 hours to me. As soon as it came in a prealarm for pressure sensor was present. While loadbanking it, unit shut off on high DPF soot level. DPF was clogged and had to get it baked out. Plugged into ECU of motor to show there was 12,000 hours on the unit. The description says 3805 hours and doesn't say a new ecm was installed. Once DPF was cleaned and new sensor installed, load banked unit again. This time alternator pulley fell off and broke.
Reply from: smlresourcesinternational1- Feedback replied by seller smlresourcesinternational1.- Feedback replied by seller smlresourcesinternational1.
Spoke with Anthony this morning about his Genset that we bought from Auction company. Auction company said that it had only 3805 hours and needed an ECM Gauge. When we received genset, we installed New ECM Gauge. Found out it also needed a New ECM. Order (1) and installed it. Ran the genset with NO ISSUES. We are working to resolve the issues stated above. Anthony is sending us repair bills along with labor charges for reimbursements.
e***_ (11)- Feedback left by buyer.
More than a year ago
Verified purchase
Seller was easy to work with and item arrived timely!